제품정보 ▒ Thermal ▒
Model : Fuse Series
SPEC : KLS5-105

Fuse and Fuse holder >> Thermal Fuse Series   KLS5-105
Dimension:(mm)           1A Series
a b c d e
6.5±0.5 38±3 Φ0.54±0.05 Φ2.1±0.1 2.4 or below
1A  Series
Model No. Rated functioning temp.
(Tf)
Fusing-off temperature Holding temperature(Th) Maximum temp. limit
(Tm)
Rated current
(Ir)
Rated voltage(Ur)

Safety approval

RoHS Compliace

UL CUL VDE PSE CCC EK
1A 115℃ 112±3℃ 85℃ 180℃ 1A 250Vac
1A 125℃ 120±3℃ 97℃ 180℃ 1A 250Vac
1A 130℃ 126±2℃ 102℃ 180℃ 1A 250Vac
1A 135℃ 131±3℃ 105℃ 180℃ 1A 250Vac
1A 138℃ 135±2℃ 108℃ 180℃ 1A 250Vac
1A 150℃ 145±3℃ 120℃ 180℃ 1A 250Vac
Dimension:(mm)         2A  Series
a b c d e
9.0±0.5 38±3 Φ0.54±0.05 Φ2.5±0.1 3.3 or below
2A  Series
Model No Rated functioning temp
(Tf)
Fusing-off temperature Holding temperature(Th) Maximum temp. limit(Tm) Rated current
(Ir)
Rated voltage
(Ur)

Safety approval

RoHS Compliace

UL CUL VDE PSE CCC EK
2A 115℃ 112±3℃ 85℃ 180℃ 2A 250Vac
2A 125℃ 120±3℃ 97℃ 180℃ 2A 250Vac
2A 130℃ 126±2℃ 102℃ 180℃ 2A 250Vac
2A 135℃ 131±3℃ 105℃ 180℃ 2A 250Vac
2A 138℃ 135±2℃ 108℃ 180℃ 2A 250Vac
2A 150℃ 145±3℃ 120℃ 180℃ 2A 250Vac
Dimension:(mm)      3A  Series
a b c d e
10.0±0.5 38±3 Ф0.6±0.02 Φ3.0±0.1 3.3 or below
3A     Series
Model No Rated functioning temp
(Tf)
Fusing-off temperature Holding temperature(Th) Maximum temp. limit(Tm) Rated current
(Ir)
Rated voltage
(Ur)

Safety approval

RoHS Compliace

UL CUL VDE PSE CCC
3A 84℃ 82±2℃ 55℃ 180℃ 3A 250Vac
3A 115℃ 112±3℃ 75℃ 180℃ 3A 250Vac
3A 125℃ 120±3℃ 85℃ 180℃ 3A 250Vac
3A 130℃ 126±2℃ 90℃ 180℃ 3A 250Vac
3A 135℃ 131±3℃ 90℃ 180℃ 3A 250Vac
3A 138℃ 135±2℃ 95℃ 180℃ 3A 250Vac
3A 150℃ 145±3℃ 105℃ 180℃ 3A 250Vac
Dimension:(mm)       5A   Series
a b c d e
11.5±0.5 38±3 Φ0.6±0.02 Φ3.3±0.2 3.6 or below
5A   Series
Model No Rated functioning temp
(Tf)
Fusing-off temperature Holding temperature(Th) Maximum temp. limit(Tm) Rated current
(Ir)
Rated voltage
(Ur)

Safety approval

RoHS Compliace

UL CUL VDE PSE CCC
5A  84℃ 82±2℃ 55℃ 180℃ 5A 250Vac
5A  115℃ 112±3℃ 75℃ 180℃ 5A 250Vac
5A  125℃ 120±3℃ 85℃ 180℃ 5A 250Vac
5A  130℃ 126±2℃ 90℃ 180℃ 5A 250Vac
5A  135℃ 131±3℃ 90℃ 180℃ 5A 250Vac
5A  138℃ 135±2℃ 95℃ 180℃ 5A 250Vac
5A  150℃ 145±3℃ 105℃ 180℃ 5A 250Vac
Rated functioning temperature(Tf) The temperature at which a Thermal Cutoff changes its state of conductivity to open circuit detection curret.The tolerance according to IEC60691 is from +0 to-10℃.(With Japan Electrical Appliance and Material Law,on the other hand,they must function in the tolerance range of ±7℃.).
Fusing(cut)-off temperature The fusing-off temperature indicates value measured in silicon oil with a temperature increased by 0.5-1℃ per minute and a detective current 100mA or less.
Holding temperature(Th) The maximum temperature at which a thermal Cutoff will not cause a change in state of conductivity to open circuit while conducting rated current for 168 hours. This rating is required by safety standards based on IEC60691.
Maximum temperature limit(Tm) The maximum temperature at which a Thermal Cutoff can be maimtained for 10 minutes without reclosing.This rating is requirde by safety standards based on IEC60691.
Rated current(Ir) The allowable maximum current which a Thermal Cutoff is able to carry.
Rated current(Ur) The allowable maximum voltage which a Thermal Cutoff is able to be applied.